Failure to recognize esophageal intubation
A 51-year-old man was scheduled for a right knee replacement revision at a local hospital.

by Laura Hale Brockway, ELS, Vice President, Marketing
Presentation
A 51-year-old man was scheduled for a right knee replacement revision on August 3 at a local hospital. The revision was required because of loosening hardware.
The patient’s medical history included morbid obesity, asthma, hypertension, high cholesterol, and diabetes. On the morning of the surgery, the patient reported shortness of breath and wheezing. A medical assistant gave the patient albuterol to address his wheezing.
Physician action
The patient was taken to the OR and Anesthesiologist A intubated the patient. Anesthesiologist A described the events in this case in two separate narrative progress notes. According to Anesthesiologist A, the hospital asked him to write a second note because his first note lacked detail. The first set of notes were brief, because OR staff were trying to get the patient ready for transfer and Anesthesiologist A wanted the records available for transfer. There were several discrepancies between the first and second set of notes.
The two sets of notes differ following the patient’s intubation. The first note stated the patient was taken to the OR at 7:50 a.m. He was intubated with a 7.0 endotracheal tube. The first note also stated that at 7:58 a.m., the patient’s end-tidal CO2 (EtCO2) was lost and dexamethasone, propofol, albuterol, and three doses of epinephrine were given. The second note stated that at 7:50 a.m. the EtCO2 decreased and airway pressures began to rise. The notes show an 8-minute discrepancy for when the EtCO2 started to decrease.
The first note implied that Anesthesiologist A thought the patient was in bronchospasm. The second note explicitly stated that Anesthesiologist A believed the patient was in bronchospasm. The second note documented that an anesthesia tech came into the OR and pushed the endotracheal tube in 2 cm and taped the tube. There is no mention of this in the first note. The patient’s O2 saturations decreased to the low- to mid-70s. His stats remained at that rate until 8:05 a.m. when they dropped into the high 50s and low 60s.
It was discovered that the endotracheal tube was in the esophagus. Anesthesiologist A used a glidescope to reposition it. The patient became bradycardic and shortly after was in cardiac arrest. He was defibrillated five times and received epinephrine and amiodarone. The patient went into sinus rhythm. An arterial line and central line were placed. He was given norepinephrine for five minutes, and his oxygen saturations improved. The patient was taken to the PACU.
The patient was later transferred to a regional medical center for a higher level of care and a neurology consult. Despite treatment at the regional medical center, the patient did not recover and was declared brain dead. Life support was withdrawn and the patient died.
The autopsy report listed the cause of death to be the result of a recent hypoxic/ischemic brain injury due to esophageal intubation during anesthesia induction. The patient’s morbid obesity was listed as a contributing factor.
Allegations
A lawsuit was filed against Anesthesiologist A and the hospital. The allegations were:
- failure to provide proper anesthesia causing anoxic brain injury and death (Anesthesiologist A);
- failure to evaluate and monitor the patient (hospital);
- failure to perform and document a complete medical examination (hospital); and
- and failure to stabilize the patient for transfer (hospital).
Legal implications
The plaintiff’s anesthesiology consultant stated that the patient’s anoxic brain injury occurred because the endotracheal tube was placed in the esophagus instead of the trachea. The delayed recognition and correction of this issue led to the hypoxia, cardiac arrest, and brain injury.
The plaintiff’s consultant’s criticism mirrored that of defense consultants — that Anesthesiologist A should have considered esophageal intubation when treating the bronchospasm. This caused a delay in the discovery of a mispositioned endotracheal tube. However, one defense consultant stated that she understood how it might have been possible for Anesthesiologist A to pursue treatments for bronchospasm in this patient who had a history of asthma.
The plaintiff’s consultant made several concessions that benefited the defense of this case. He stated that an esophageal intubation is not a violation of the standard of care and can happen in any number of situations. He also stated that Anesthesiologist A used reasonable methods to confirm proper placement of the endotracheal tube by noting bilateral breath sounds, noting the presence of EtCO2 after intubation, and confirming the patient’s abdomen was not distended.
Documentation was a complicating factor in this case. The two versions of the anesthesia notes were inconsistent with each other and were also inconsistent with the notes from the other providers. It was difficult to establish a valid chronology of events.
Disposition
This case was settled on behalf of Anesthesiologist A. The outcome of the case against the hospital is unknown.
More on failure to diagnose.
Risk management for anesthesiologists.
Disclaimer
This closed claim study is based on an actual malpractice claim from Texas Medical Liability Trust. This case illustrates how action or inaction on the part of the physicians led to allegations of professional liability, and how risk management techniques may have either prevented the outcome or increased the physician’s defensibility. This study has been modified to protect the privacy of the physicians and the patient.
Subscribe to Case Closed to receive insights from resolved cases.
You’ll receive two closed claim studies every month. These closed claim studies are provided to help physicians improve patient safety and reduce potential liability risks that may arise when treating patients.
Related Case Studies
Discover more insights, stories, and resources to keep you informed and inspired.

Failure to respond to abnormal liver function test results

Failure to timely diagnose and treat urinary tract infection